Concrete Spacer - Single Size

 

1. Code: CSS030F

Detail:

- Apply for Cover Size with the height 30mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Clomun, Beam. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS030F-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Column

Beam

30

≥08 KN ...............

 ≤10 KN

72

347

 

2. Code: CSS040F

Detail:

- Apply for Cover Size with the height 40mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Clomun, Beam. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS040F-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Column

Beam

40

≥10 KN ...............

  ≤12 KN

96

260

 

 3. Code: CSS050F

Detail:

- Apply for Cover Size with the height 50mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Clomun, Beam. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS050F-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Column

Beam

50

≥10 KN ...............

  ≤12 KN

120

208

 

4. Code: CSS075F

Detail:

- Apply for Cover Size with the height 75mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Clomun, Beam. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS075F-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Column

Beam

75

≥10 KN ...............

  ≤12 KN

240

104

 

5. Code: CSS050U

Detail:

- Apply for Cover Size with the height 50mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Beam, Foundation. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS050U-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Beam

Foundation

50

≥3 KN ...............

≤5 KN

168

148

 

6. Code: CSS070U

Detail:

- Apply for Cover Size with the height 70mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Beam, Foundation. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS070U-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Beam

Foundation

70

≥3 KN ...............

≤5 KN

240

104

 

7. Code: CSS090U

Detail:

- Apply for Cover Size with the height 90mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Beam, Foundation. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS090U-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Beam

Foundation

90

≥3 KN ...............

≤5 KN

336

74

 

8. Code: CSS110U

Detail:

- Apply for Cover Size with the height 110mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Beam, Foundation. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS110U-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Beam

Foundation

110

≥4 KN ...............

≤5 KN

528

47

 

9. Code: CSS10063R

Detail:

- Apply for Cover Size with the height 100mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Foundation. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer Single size
  • Concrete Spacer Single size
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS10063R-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Foundation

100

≤11 KN

600

41

 

10. Code: CSS020C

Detail:

- Apply for Cover Size with the height 20mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Column, Beam. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer - wire
  • Concrete Spacer - wire
 

 
 PDK2049-YL copy

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Column

Beam

20

≤3 KN

48

 

520 


11. Code: CSS025C

Detail:

- Apply for Cover Size with the height 25mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Column, Beam. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer - wire
  • Concrete Spacer - wire
  • Concrete Spacer - wire
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS025C-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Column

Beam

25

≤3 KN

72

347

 

12. Code: CSS040C

Detail:

- Apply for Cover Size with the height 40mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Column, Beam. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer - wire
  • Concrete Spacer - wire
  • Concrete Spacer - wire
 

 
 Concrete Spacer Single Size Goi ke be tong don kich thuoc CSS040C-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Slab

Column

Beam

40

≥5 KN ...............

≤10 KN

168

148

 

 13. Code: CSS050C

Detail:

- Apply for Cover Size with the height 50mm form the steel bar to the bottom based on the side be used. Easy use for Slab, Column, Beam. Restrictions floor cracking, sagging floors

- High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2)

- Ensure the structural design of the steel frame

- Dimension and quality are stable. Prevent reinforcement steel from corrosion

- Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material

  • Concrete Spacer - wire
  • Concrete Spacer - wire
  • Concrete Spacer - wire
 

 
 Concrete Spacer Single SizeGoi ke be tong don kich thuoc CSS050C-1

Perfect location to use

Cover Size (mm)

Breaking Load (KN)

Average Weight (g/pcs)

Packing (pcs/bag)

Sàn

Cột

Dầm

50

≥20 KN ...............

≤25 KN

288

86

 

Other names: Spacer vn, concrete spacer, concrete spacer - single size concrete Spacer Viet Nam, Spacer VN, , Hight Concrete spacer Streng, Slab concrete spacer, Column Concrete Spacer, Wall Concrete Spacer, Slab Concrete Cover block, Plastic Spacer, Steel Spacer, Slab Steel Spacer, Column Steel Spacer, Spacer Bar, Cement spacer, , spacer china, Concrete spacer china, concrete spacer – circular, concrete spacer – single size, concrete spacer multi size, concrete spacer with wire, spacer wire, spacer concrete, single concrete spacer, concrete cover size, slab concrete cover, cover block, concrete cover

 

Sales Hồ Chí Minh
Telephone number of Sales Hồ Chí Minh 0917 129 900
Sales Hà Nội
Telephone number of Sales Hà Nội 0913 018 370
Technical
Telephone number of Technical 0909 956 900
Marketing
Telephone number of Marketing 012 9544 7889
SlideBar