1. Code: CSC2012
Detail: - Apply for Cover Size with the height 20mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 12mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
20 |
≤03 KN |
96 |
260 |
2. Code: CSC2512
Detail: - Apply for Cover Size with the height 25mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 12mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
25 |
≤03 KN |
168 |
148 |
3. Code: CSC2716
Detail: - Apply for Cover Size with the height 27mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 16mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
27 |
≤03 KN |
240 |
104 |
4. Code: CSC3020
Detail: - Apply for Cover Size with the height 30mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
30 |
≤05 KN |
312 |
80 |
5. Code: CSC3520
Detail: - Apply for Cover Size with the height 35mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
35 |
≤07 KN |
408 |
61 |
6. Code: CSC4020
Detail: - Apply for Cover Size with the height 40mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
40 |
≤7 KN |
528 |
47 |
7. Code: CSC4520
Detail: - Apply for Cover Size with the height 45mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
45 |
≤10 KN |
600 |
41 |
8. Code: CSC5020
Detail: - Apply for Cover Size with the height 50mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
50 |
≤10 KN |
528 |
47 |
9. Code: CSC5520
Detail: - Apply for Cover Size with the height 55mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
50 |
≤12 KN |
900 |
27 |
10. Code: CSC6020
Detail: - Apply for Cover Size with the height 60mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
60 |
≤12 KN |
1.056 |
20 |
11. Code: CSC6520
Detail: - Apply for Cover Size with the height 65mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
65 |
≤12 KN |
1.188 |
20 |
10. Code: CSC9530
Detail: - Apply for Cover Size with the height 95mm form the steel bar to the bottom based on the side be used. Easy use for Clomun, Wall, Slab. Restrictions floor cracking, sagging floors. Diameter hole is 20mm. - High compression strength. Concrete Strength reaches at least: 50mpa (500kg/cm2) - Ensure the structural design of the steel frame - Dimension and quality are stable. Prevent reinforcement steel from corrosion - Slow the melting of steel when burn. Increased waterproofing because homogeneous substance raw concrete floors. High compatibility: due to the same concrete material |
|
Perfect location to use |
Cover Size (mm) |
Breaking Load (KN) |
Average Weight (g/pcs) |
Packing (pcs/bag) |
|
Column Wall Slab |
95 |
≤12 KN |
3.360 |
10 |
Other names: Spacer vn, concrete spacer, concrete spacer - single size concrete Spacer Viet Nam, Spacer VN, , Hight Concrete spacer Streng, Slab concrete spacer, Column Concrete Spacer, Wall Concrete Spacer, Slab Concrete Cover block, Plastic Spacer, Steel Spacer, Slab Steel Spacer, Column Steel Spacer, Spacer Bar, Cement spacer, , spacer china, Concrete spacer china, concrete spacer – circular, concrete spacer – single size, concrete spacer multi size, concrete spacer with wire, spacer wire, spacer concrete, single concrete spacer, concrete cover size, slab concrete cover, cover block, concrete cover, Cover circular, cover spacer circular, circular concrete spacer, concrete spacer circular.